Johnstown
Local Reviews
for Johnstown, PA
Great Service
Wes - Johnstown, PA 15904
Job performed professionally and in a timely manor. Would recommend them to anyone.
Bill B.
Annual Backflow Inspection Backflow Inspection
Bill B.
Sprinkler Inspection Annual Sprinkler System Inspection
Bill B.
confirmed with Brenda Sprinkler Inspection
Bill B.
Fire Pump and Sprinkler Inspection Confirmed with Deb for 8am -Set alarms off ASAP, (may be tours taking place starting at 10am).
Jason M.
Special Hazards Inspection
Bill B.
confirmed with Carol for 12noon. Annual Sprinkler inspection Sprinkler Inspection
Jason M.
Sprinkler Inspection
Jason M.
Sprinkler Inspection Deficiency: Both risers are due for 5 year internal inspection and gauge replacement FDC hydro test is due Need sign for control valve at FDC 5 year internal inspection ( 2 risers) 4 water gauges FDC hydro test ( no check valve, control valve at FDC in battery room) Need sign for Fire Company at FDC control valve ( Open to charge line)
Bill B.
Notice of Non Compliance and Repair Proposal Liberty Fire Solutions recently inspected/serviced the fire sprinkler system at your establishment in accordance with applicable state statutes, local fire codes and NFPA guidelines. While inspecting/servicing your fire sprinkler system, it was determined to be "Non-Compliant" per local fire codes. The attached proposal summarizes the non-compliance issues that were found during the inspection/service and the costs and actions needed to correct them. The sprinkler systems are due for a 5 year internal inspection and gauge replacement per NFPA 25. NFPA 25 REQUIREMENTS FOR 5 YEAR TESTING: 13.4.1.2 Alarm valves and their associated strainers, filters, and restricted orifices shall be inspected every 5 years unless tests indicate a greater frequency is necessary 13.4.2.1 Check valves shall be inspected internally every 5 years to verify that all components operate correctly, move freely and are in good condition 14.2.1.1 An assessment of the int
Bill B.
due date 2/16 Sprinkler Inspection
Bill B.
Sprinkler Inspection Annual Sprinkler System Inspection
Bill B.
Sprinkler Inspection confirmed with Brenda for 8:30am. check when last 5 year was completed.
Bill B.
Confirmed with David for 8am Portable Extinguishers and Kitchen Suppression Inspection
Bill B.
Sprinkler Inspection Confirmed with Robert Gilbert for 8:30am. Annual Sprinkler
Jason M.
Delivered gas valve for plumber
Jason M.
Bill B.
Backflow and Sprinkler Inspection Confirmed with Charles Hanik Annual SP and Backflow
Bill B.
Quarterly sprinkler system inspection 3 - Wet Risers 2 - Dry Risers